Lesson 4 - Using dialog history lists and the toolbar
Now it is time to learn about some additional features of Wintrack's
user interface: dialog history lists and the toolbar. We will do this
while adding more cases and variables to the scrollsheet we have built
in lesson 3.
Opening documents using the toolbar...
- Click the Open Scrollsheet button of the toolbar
while pressing and holding down the Shift key. The Open
Scrollsheet dialog is displayed:
- Press the button of the dialog field labeled scrollsheet file.
A standard Windows File Open dialog box is displayed. Use
it to select the file TUTOR1.WTB in your WINTRACK directory. This
is the file you have created during the previous lesson. Press Ok
to close the standard File Open dialog.
- In the dialog field Window, click minimize: Wintrack will display
the scrollsheet as an icon.
- Press Ok to close the dialog box. Wintrack opens the scrollsheet.
- Click the Open Case Document button of the toolbar
while pressing and holding down the Shift key. The Open
Case Document dialog is displayed:
- Press the button located next to the dialog field labeled case
file. The drop down history list of the field opens. It contains
name and path of the case documents SWIM1.WTR to SWIM3.WTR. All
dialog fields in Wintrack have such a history list from which you
can pick recently made entries or selections. Select the file SWIM2.WTR.
- In the dialog field Window, click minimize.
- Press Ok to close the dialog box. Wintrack opens the case document
SWIM2.WTR.
- Click the Analyze button of the toolbar
while pressing and holding down the Shift key. The Analyze
Case Document dialog is displayed:
- From the list box located next to the option labeled Variable
definition, select the variables jmp and qog.
- As you made selections in the list box, part of the dialog fields
located underneath it may have changed their activation state. For
now, you can accept the default values contained in these fields.
- In the dialog field labeled Report, select the option merge.
- In the dialog field labeled Trial range and blocks, set block
size to 0.
- In the dialog field labeled Time window, select the option from
begin and enter 120 for duration [s] and 0 for offset [s].
- Click Ok to close the dialog box and start the analysis.
- Click the Open Case Document button of the toolbar
while pressing and holding down the Shift key. The Open
Case Document dialog is displayed. Open the case file SWIM3.WTR.
You may again use the history list of the dialog field labeled case
file.
- Click the Analyze Merge button of the toolbar
without pressing the Shift key. The Analyze
Case Document dialog is not displayed. Instead, Wintrack processes
SWIM3.WTR using the same selections you made when using the command
the last time.
- Double click the scrollsheet icon to restore its window. If you scroll
to the right, you will notice that two columns have been added to the
scrollsheet, named jmp and qog.
- Select Close All from Wintrack's Window menu. Click No whenever you
are asked whether you wish to save a document before closing.
Lesson 5 - Acquiring new data demonstrates how